Cycle-Aware Autoencoder with Cross-SignalConsistency for Railway Door Anomaly Detection
תקציר מקורי באנגליתarXiv:2609.39035v1 Announce Type: new Abstract: Passenger access doors are safety-critical subsystems in railway vehicles, yet detecting abnormal door behavior in real operation is challenging because faults are rare, diverse, and often unlabeled. This paper addresses railway door condition monitoring as a cycle-level unsupervised anomaly detection problem, where each complete opening-dwell-closing cycle is treated as a single monitoring unit. We propose the Temporal Cycle-Aware Attention Autoencoder with Cross-Signal Consistency (TCAA-CS), trained exclusively on nominal cycles. It combines a dual-stream encoder that processes continuous physical measurements (position, current, voltage) and binary logical states (door-closed, door-locked) through separate 1D-CNN branches, an LSTM encoder